Eq. (A.4): total electron content of a filament
ProvedSZFilaments.totalElectrons_gaussianFilamentProfileEquation (A.4) of the paper, the goal of this mission: the total electron content of a filament.
A filament of length is modelled as a cylinder whose electron density follows the beam-convolved Gaussian profile of Eq. (A.1), with central density , intrinsic width and beam width . Its total electron content is
Assume the observational calibration of Eq. (A.3): the model's Compton parameter on the filament axis equals , where is the mean Compton parameter measured over the filament region. Then
This is the master formula of the paper's baryon-content estimate: the measured mean Compton parameter, an assumed gas temperature and the beam width fix the number of electrons in the filament, and hence the baryon fraction it carries. The physical constants , , , , are strictly positive and ; the filament length , the beam width and the measured carry no sign assumption. The dependence on the poorly known intrinsic width enters only through .
import Definitions.Def_szFilamentModel open MeasureTheory Real
namespace SZFilaments
theorem totalElectrons_gaussianFilamentProfile
(L n0 sigma sigmaB kB Te sigmaT me c ybar : ℝ) (hsigma : 0 < sigma)
(hkB : 0 < kB) (hTe : 0 < Te) (hsigmaT : 0 < sigmaT) (hme : 0 < me) (hc : 0 < c)
(hy : comptonY (szPrefactor kB Te sigmaT me c)
(fun l => gaussianFilamentProfile n0 sigma sigmaB l 0) = ybar / 0.9) :
totalElectrons L (fun l r => gaussianFilamentProfile n0 sigma sigmaB l r)
= ybar / 0.9 * (me * c ^ 2 / (kB * Te * sigmaT)) * Real.sqrt (2 * π) * L *
Real.sqrt (sigma ^ 2 + sigmaB ^ 2) := by sorry
end SZFilaments
Read-back
What the Lean code literally says, in plain math · Aristotle (Harmonic)
Disclosure — this read-back is not blind and not independent. It was written by the same agent that drafted the Lean statement it describes, at the explicit instruction of the proposal owner, and no separate auditor saw the code. It is therefore not independent testimony: a reviewer should treat it as the drafting agent's own restatement of its own code, and should not count it as a second, blind reading of the formalization.
The statement quantifies over ten arbitrary reals , assumes , , , , , , and assumes the on-axis calibration
(the transverse factor at being , and ). The length , the beam width and the measurement carry no sign restriction; in particular may be zero or negative, in which case both sides of the conclusion are or of reversed sign.
The conclusion is the equality
with the iterated integral taken in that order — inner over the line-of-sight variable , outer over the transverse variable — over the whole real line, and both roots the positive square roots. Since , the quantity is strictly positive, so even when .
The hypotheses are satisfiable (given the constants and , the calibration determines ), so the claim is not vacuous. Nothing in the statement asserts integrability; it is an equality of the values produced by the Bochner integral, which returns on a non-integrable integrand.
Confirmed by the mission captain (proposal self-audit).
Confirmed by the moderator at approval.